题库预览
2. INSPECTION PRACTICE 2.1 CERTIFICATES/DOCUMENTS/ RECORDINGS Calibration cert of Oxygen analysis meter /portable gas detector Recordings of Oxygen content in IG (Refer to SMS) Maintenance recordings... (Refer to SMS) 2.2 EQUIPMENTS Wheel house, C.C.R, Main Deck, Engine Room... 2.3 OPERATION/TESTING Alarm Testing, Demonstration, Oxygen content in Cargo tanks measuring... Clear Grounds: (1) Evidence of leaks in the inert gas piping on deck; (2) Faulty portable gas detectors, lack of spare parts, or inability to provide test certificates; (3) Malfunctioning indicator lights on the inert gas system control panel; (4) Oxygen analyzer panel records showing oxygen conten repeatedly exceeding 5% for prolonged periods. CCR(Cargo Control Room): (1) Check whether any abnormal alarms are on IG indicating penal or not ; (2) Confirm Oxygen content not more than 5% by volume and gas pressure not less than 100 mm water gauge on Oxygen analysis meter, and review the recording history. (3) Check the temperature of the inert gas at the discharge side of the system, whenever it is operating. (4) Test all indicators condition on IG indicating penal, confirm relevant valves condition are correctly indicated. (5) Test audible and visual alarms which are provided, based on the system designed, for the system indicating: ① oxygen content in excess of 5% by volume; ② failure of the power supply to the indicating devices; ③ gas pressure less than 100 mm water gauge. The alarm arrangement shall be such as to ensure that the pressure in slop tanks in combination carriers can be monitored at all times; ④ High-gas pressure;【缺少答案,请补充】(含图)(含图)(含图)(含图)(含图)